SIN-MPP1000 Multi-parameter analyzer

PH /ORP range: 0-14 pH, ±2000 mV

Turbidity range: 0-1NTU / 0-20NTU / 0-100NTU / 0-2000NTU

Conductivity range: (0~20000)uS/cm; Pure water sensor: (0~20)uS/cm

Dissolved oxygen range: 0-20mg/L

  • Specification 

Item Index Value
System working power (220±22)VAC, (50±1)Hz
Power 30W
Cabinet size 800mm*506mm*180mm (standard version)
Weight about 15Kg
Storage temperature 4℃~+50℃
Working temperature 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module)
Working humidity ≤95%RH (no condensation)
Inlet flow 500-1000 mL/min
Inlet pressure < 3kg/cm2
Communication interface RS485 Modbus RTU communication protocol + air data interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-2000NTU
Resolution 0-1NTU / 0-20NTU / 0-100NTU:0.0001NTU 0-2000NTU:0.001NTU
Lower detection limit 0.005NTU
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 0-1NTU/0-20NTU/0-100NTU:2% or ±0.02NTU, whichever is greater
0-2000NTU:10% or ±0.5NTU, whichever is greater
Repeatability ≤1%
Response time ≤120s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Lower detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP(optional) Range 0-14 pH, ±2000 mV (ORP)
Resolution 0.01 pH, ±1 mV (ORP)
Accuracy ±0.1 pH, ±20 mV (ORP) or ±2%
Repeatability ±0.1 pH, ±10 mV (ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range -20℃ ~ +85℃
Resolution 0.1℃
Accuracy ±0.5℃
Repeatability ≤0.5℃
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range (0~20000)uS/cm
Pure water sensor: (0~20)uS/cm
Accuracy ± 0.8% F.S pure water sensor: 3% F.S
Repeatability ≤0.4%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months
Dissolved oxygen (Optional) Range 0-20mg/L
Accuracy ±0.3mg/L
Repeatability ≤±1.5%
Response time ≤30 seconds
Recommended maintenance period 1-3 months
Expansion port Port type RS485, 4-20mA

 

  • Introduction

The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.

GET A FREE QUOTE!

CONTACT US

Sinomeasure Automation

Sinomeasure has been dedicated to industrial process automation for decades, focusing on the research, development, and manufacturing of precision sensors and instruments. Our main products include water analysis instruments, recorders, pressure transmitters, flowmeters, and other field instruments used in a wide range of process industries.

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.