K-G60 Fixed Gas Detector/Transmitter with Temperature compensation for gas
Target gas: Combustible gases and Toxice gases
Sample manner: Natural diffusion
Unit: %LEL, ppm, %VOL
Response time: <20s
Load resistance (4~20)mA: ≤250 Ω
Accuracy: F.S.±3%
Repeatability: F.S.±1%
Working voltage: DC24V±15%
● High sensitivity and long life
● Low drift and reliable performance
● Self-check of sensor fault
● LCD display,menu operation
● Temperature compensation
● Explosion proof design
● Easy to install
● Can be worked stand alone
● DC24V external power optional
● 433Hz wifi optional
● Romote control
● No need to calibrate
Target gas | Combustible gases and Toxice gases |
Sample manner | Natural diffusion |
Sensor type | Catalytic gas sensor for combustible gas, PID for VOC Electrochemical gas sensor for toxic gas, infrared for CO2 |
Unit | %LEL, ppm, %VOL |
Response time | <20s |
Load resistance (4~20)mA | ≤250 Ω |
Accuracy | F.S.±3% |
Repeatability | F.S.±1% |
Working voltage | DC24V±15% |
Working condition | Combustible gas: Tem.: -40℃~70℃ Toxic gas: Tem.: -20℃~50℃ |
Hum. | ≤95%RH no con. |
Explosion-proof | ExdⅡCT6 |
Protection degree | IP65 |
Power Consumption | ≤3W |
Cable | ≥ RVVP 1.5 mm2×3 |
Transmit distance | ≤1000m |
Pressure | 86kPa~106kPa |
Output signals | 4~20mA,Two level free contact (0.5A/AC220V) |
Install screw thread | G3/4 |
Colour | Yellow |
Weight | 1600g |
Shell Material | Aluminum |